The type KV-1 is a high-speed single phase undervoltage relay particularly suited for applications where high drop-out ratio is desirable. This relay may be used for high-speed carrier tripping or carrier starting for phase fault clearing of a weak-feed terminal. Hot-Line reclosing is another application for this relay.
The type 47 relays provide three-phase undervoltage and phase-sequence protection for protection of motors, or for the initiation of bus transfer. A major benefit of this relay is that is is more sensitive to unbalanced voltages ("single-phasing") than many of the comparable electro-mechanical types.
Your Privacy is important for us : Your Name Email address, Phone Numbers will not be disclosed to the employers until and unless approved by you, so provide your correct email address for futher correspondance
Please note that we have direct contact in most of the companies listed here,
we will forward your resume to the HR department of the company. In case we
are not in direct touch with the company, then your resumes will be forwarded
to the authorized Placement Consultants of the respective company. We do not
take the guarantee that your resume will be selected or not by the company.
CM-ESS single-phase over- or undervoltage monitors are used to monitor the proper operation of equipment and control systems. Adjustable voltage threshold values (trip points) ensure the voltage remains within an acceptable range. Select either over- or undervoltage monitoring. If the voltage exceeds the upper limit or falls below the lower limit the output relay energizes / de-energizes. An adjustable tripping delay prevents nuisance tripping. Product range overview Over- or undervoltage monitoring with CM-ESS.1, CM-ESS.2 and CM-ESS.M.
The CM-PVS is a three-phase monitor. It is able to monitor the phase parameters phase sequence, phase loss, over- and undervoltage. Operating mode Over- and undervoltage monitoring If all three phases are present with correct voltage, the output relay is energized. If the voltage to be monitored exceeds or falls below the set threshold value, the output relays are deenergized undelayed or delayed (0.1-10 s), depending on the set time delay. The fault type is indicated by LEDs. The output relays re-energize automatically, instantaneously or with delay (0.1-10 s), depending on the set time delay, as soon as the voltage
The CM-MPS is a three-phase monitor. It is able to monitor the phase parameters phase sequence, phase loss, over- and undervoltage and phase unbalance. The CM-MPS is a multifunctional 3-phase monitor. It monitors the phase parameters, phase sequence, phase loss, over and undervoltage and phase unbalance. The threshold values for over and undervoltage are adjustable in the range of Vmin 160-380 V and Vmax 220-500 V; resp. The CM-MPS detects the interruption of the neutral in the main to be monitored by means of phase unbalance evaluation. Determined by the system, in case of unloaded neutral, i. e. symmetrical load
The MMCO greatly simplifies overcurrent relay selection and enhances the protective relay function. It can be programmed to fit virtually any overcurrent application, and provides valuable fault information not available from conventional relays. Communications options provide immediate retrieval of fault and status data, and the ability to reset or reconfigure the relay remotely.
The MMCO uses microprocessor technology to incorporate eight time curve families into one relay. Any traditional COtype curve family may be selected from the relay’s memory.
Often there is the application requirement to trip more than one breaker when the seriousness of the fault condition warrants it. With today’s protection relay technology, there is most likely only one relay available that must be tasked to trip all essential breakers. However, this lone relay will have only one trip signal that would not only have to be duplicated, but also extended to trip those extraneous breakers.
Advanced relay technology allows for programming the master trip signal to multiple programmable output contacts to wire to the multiple trip circuits. However, if the trip signal resets itself or drops out
CA generator differential relay is a single phase, induction disc type with inverse timing characteristics. It is provided with one operating winding and two restraining windings without taps. Designed for 2-winding transformer protection, the CA transformer differential relay has a constant percentage differential characteristic and inverse timing. It is a single-phase unit, and three relays are used for three-phase transformer protection The CA-16 relay is a single-phase differential relay used for protection of multicircuit buses up to a total of six circuits. The CA-26 relay provides differential protection for both 2- and 3-winding transformers. It is also suitable for combination
The MMCO greatly simplifies overcurrent relay selection and enhances the protective relay function. It can be programmed to fit virtually any overcurrent application, and provides valuable fault information not available from conventional relays. Communications options provide immediate retrieval of fault and status data, and the ability to reset or reconfigure the relay remotely.
The MMCO uses microprocessor technology to incorporate eight time curve families into one relay. Any traditional COtype curve family may be selected from the relay’s memory.
The earth-fault relay SPAJ 110 C is designed to be used for selective earth-fault protection, either primary or back-up protection, in solidly earthed or low-resistance earthed power systems. The relay has two protection stages: a low-set overcurrent stage I 0 > and a high-set overcurrent stage I 0 .
The low-set stage operates with definite-time characteristic or with inverse-time characteristic, while the high-set stage operates with definite time characteristic only. The earth-fault relay is used both as primary and back-up earth-fault protection relay for feeders, transformers, generators and motors. The relay can be configured to cooperate with a residual voltage
The type KD relay is a polyphase compensator type relay which provides a single zone of phase protection for all three phases. It provides instantaneous tripping for all combinations of phase-to-phase faults, two-phase-to-ground faults, and three-phase faults. Type SDG-1T, 2T and 4T relays are single zone ground distance relays used to detect faults on subtransmission or transmission lines. HZM relay is a three-element high speed relay of the modified zone distance type operating instantaneously or with a time delay depending upon the location of the fault.
The SPAF frequency relays are intended for protection against frequncy abnormalities in generators, motors and network. The frequency relay SPAF 340 C is used for load shedding in situations where power consumption exceeds the available power of the network. In such a situation of unbalance, the network frequency tends to fall. The frequency relay can control four circuit breakers, allowing four feeders to be disconnected from the network, one by one.
Should the power deficiency still persist, the relay disconnects the plant for island operation. The operation of the relay can be based on set frequency values (f
The type KD relay is a polyphase compensator type relay which provides a single zone of phase protection for all three phases. It provides instantaneous tripping for all combinations of phase-to-phase faults, two-phase-to-ground faults, and three-phase faults.
The KST relay is used with another distance relay such as a KD-3 relay or the 3phase unit of a KD-4, KD-10, or a KD-11 to sense an out-of-step condition on a power system and to intiate tripping. When fault occurs within the reach of the KST, the distance unit and the KD-10 3-phase units operate essentially simultaneously and, for fault removal, reset essentially
The high threshold AR is a sensitive high speed auxiliary relay with 4 normally open contacts designed to be secure against misoperation due to inadvertent grounding of a station battery or the trip lead. With the battery balanced with respect to ground, the maximum momentary voltage that can be applied to an auxiliary relay for either of these ground is half battery voltage. The operating level of the high threshold AR exceeds these levels. The type ARS relay is composed of 1 or 2 AR units with series resistors, a printed circuit module, and indicating contactor switches (ICS) when required.
The SPAG 310 C numerical generator protection relay applies for the protection of small and medium sized power generators. The generator protection relay is used in small hydro-power plants, thermal power stations and other stationary power plants. Further, the relay is approved for use in marine and off-shore applications on board large passenger ferries, service vessels, oil-drilling platforms, maintenance platforms, accommodation platforms, ice-breakers, etc.
Off-the-shelf generator protection relay for small and medium sized power generators
Three-phase time overcurrent and short-circuit protection, Single-stage reverse power protection. Two-stage overvoltage protection, Compact and robust mechanical design in an aluminium case to IP 54, Local
The AR relay is a four-pole auxiliary type relay designed for ultra high speed circuit breaker tripping duty in protective relaying systems. It is well suitable for bus arrangements where more than one breaker must be tripped. The relay mayalso be applied to provide isolation of primary and back-up relaying, and provide high speed tripping for zone 1 faults.
The high threshold AR is a sensitive high speed auxiliary relay with 4 normally open contacts designed to be secure against misoperation due to inadvertent grounding of a station battery or the trip lead. With the battery balanced with respect to ground,
The REL300 MDAR is a full-scheme numerical line protection system, with three zones of distance protection. All measurements and logic are performed on a single microprocessor. The REL300 MDAR includes comprehensive pilot logic, overcurrent protection, single or three pole tripping, fault location and DFR recording.
The 2000R Series' External Communications Programs provide for point-to-point communications with the relay. By using ECP you can program settings, map logical inputs and outputs, and monitor the metering and event recording functions of the relay. You can also use ECP software without being connected to a relay to explore the capabilities of the relay, or
Some Random Job Vacancies and Resumes
Infosys auditors are appointed by shareholders on an annual basis, upon the recommendation of the audit committee and the board of directors as a whole. The audit committee, whose role has been clearly identified as one of monitoring audit independence, is composed entirely of independent outside directors, with one exception. Neither internal nor statutory auditors provide consulting or other services to Infosys, except for some minor services provided by KPMG with respect to legal formalities (visa requirements) in countries where Infosys is in the process of setting up offices.
SCADA/EMS (Supervisory Control and Data Acquisition/Energy Management System) supervises, controls, optimizes and manages generation and transmission systems. SCADA/DMS (Distribution Management System) performs the same functions for power distribution networks.
Most SCADA/EMS systems at that time were designed exclusively for a single customer. Power systems were vulnerable, and there was a need to develop applications and tools for preventing faults from developing into large-scale outages like the New York blackout of 1977.
Project Manager
Engg./MBAs with 5 years experience in managing/executing Software projects and
possessing business acumen, administrative skills with aggressive market orientation.
Software Developers/Programmers
BE/BTech/MCA/'B' Level having experience in the areas of VC++/ C++/ASPNET/development of database driven sites.
Multimedia Designers/Developers
Two year course in multimedia or equivalent with 1 -2 years experience in using tools like Photoshop, Flash, Action scripting etc.
Content Developers {Computer Science /Information Technology)
BE/B Tech/MCA/'B' Level with creative bent of mind and flair for writing student/curriculum oriented material in electronic form. Candidates shall be required to research content from various available references for developing materials.
Content Developers
ABB a leading manufacturer of Electrical, Circuit Breakers, Softstarters, Motor Starters, Control Relays, Contactors, Timers, Monitors, Motor Controls, HVAC controls, panel switches, pilot devices, sensors,control systems, PLC, Programmable Logic controllers, controls Panels, and systems.
ABB is a leader in power and automation technologies that enable utility and industry customers to improve performance while lowering environmental impact. The ABB Group of companies operates in around 100 countries and employs about 120,000 people.
Name: Vaibhav Desai
Objective : To achieve “Quality” in whatever I pursue by upgrading my knowledge on a regular basis.
Strengths & Skills : amazing grasping power & enthusiasm to learn new techniques to improve Quality.
Educational Qualifications : B.Com From Mumbai University
technical Qualifications : Basic Computing Skills MS-Word, MS-Excel, MS-PowerPoint Diploma in Web-DesigningTopics Covered: Html,